{"product_id":"fire-lite-es-1000x-954-point-addressable-fire-alarm-control-panel","title":"Fire-Lite ES-1000X 954-Point Addressable Fire Alarm Control Panel","description":"\u003ch2\u003eFire-Lite ES-1000X Fire Alarm Control Panel\u003c\/h2\u003e\n\u003cp\u003eFire-Lite ES-1000X Fire Alarm Control Panel is a 954-point intelligent addressable FACP for larger commercial life-safety systems. It includes one Signaling Line Circuit (SLC) and a preinstalled IP\/POTS communicator, then expands to three SLC loops with optional SLC-3LS cards for up to 954 addressable devices.\u003c\/p\u003e\n\u003cp\u003eDesigned for schools, healthcare facilities, warehouses, campuses, and other complex buildings, this 954-point fire alarm control panel supports 318 devices per loop: 159 detectors and 159 modules. Installers seeking an addressable panel with IP communicator gain USB database transfer, firmware updates, auto-programming, four programmable function keys, and a 1,000-event history file.\u003c\/p\u003e\n\u003cp\u003eThe ES-1000X supports addressable smoke, heat, and carbon monoxide detection, SWIFT wireless devices, 16 ANN-Bus annunciators, and four Class A or Class B notification appliance circuits. It is listed to UL 864, 10th edition, and carries UL, ULC, CSFM, FDNY, and FM approvals for professional fire alarm installations. It directly replaces the MS-9600UDLS.\u003c\/p\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e954-Point System Capacity:\u003c\/strong\u003e Supports larger and more complex installations with up to 954 addressable devices across three SLC loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpandable SLC Architecture:\u003c\/strong\u003e Includes one 318-device loop and accepts up to two optional SLC-3LS loop expander cards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual-Path Communications:\u003c\/strong\u003e Uses a preinstalled IPOTS-COM communicator for Ethernet IP and POTS central-station reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFour Programmable NAC Circuits:\u003c\/strong\u003e Configures each notification appliance circuit for Class A or Class B operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Programming:\u003c\/strong\u003e Supports auto-programming, USB database transfer, firmware updates, and FS-Tools configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Criteria Detection:\u003c\/strong\u003e Works with compatible addressable devices that combine smoke, heat, and carbon monoxide sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSWIFT Wireless Support:\u003c\/strong\u003e Integrates compatible wireless devices through the built-in SWIFT display driver and annunciator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Panel System Management:\u003c\/strong\u003e Provides an 80-character backlit LCD, programmable function keys, status indicators, and a 1,000-event history.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Fire-Lite Alarms by Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e ES-1000X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributor Part Number:\u003c\/strong\u003e FL-ES1000X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Intelligent addressable fire alarm control panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Wired\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Replacement:\u003c\/strong\u003e MS-9600UDLS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eSystem Capacity\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Addressable Device Capacity:\u003c\/strong\u003e Up to 954 devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalled SLC Loops:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum SLC Loops:\u003c\/strong\u003e 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevices per SLC Loop:\u003c\/strong\u003e 318 total, including 159 detectors and 159 modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Zones:\u003c\/strong\u003e 256\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnnunciator Capacity:\u003c\/strong\u003e Up to 16, with 8 per ANN-Bus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum SLC Wiring Distance:\u003c\/strong\u003e 10,000 ft in LiteSpeed mode with twisted, unshielded wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSLC Circuit Classes:\u003c\/strong\u003e NFPA Class A, Class B, and Class X\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent History:\u003c\/strong\u003e 1,000 events\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eCommunications and Programming\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-In Communicator:\u003c\/strong\u003e Preinstalled IPOTS-COM Ethernet IP and POTS central-station communicator\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Communications:\u003c\/strong\u003e Compatible CLSS or GSM central-station communicators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgramming:\u003c\/strong\u003e Built-in programmer and optional FS-Tools utility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgram Transfer:\u003c\/strong\u003e USB upload and download using a compatible flash drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Updates:\u003c\/strong\u003e USB flash-drive support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffline Programming Connection:\u003c\/strong\u003e Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e Integral 80-character backlit LCD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction Keys:\u003c\/strong\u003e 4 programmable keys\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWireless Compatibility:\u003c\/strong\u003e SWIFT wireless devices\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eNotification Circuits and Relays\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNotification Appliance Circuits:\u003c\/strong\u003e 4 independently programmable Class A or Class B circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum NAC Current:\u003c\/strong\u003e 3 A special application or 300 mA regulated per circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShared 24 VDC System Power:\u003c\/strong\u003e 8 A maximum across NAC and auxiliary power circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrobe Synchronization:\u003c\/strong\u003e Selectable synchronization for compatible System Sensor, Wheelock, and Gentex devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable Relays:\u003c\/strong\u003e 2 Form-C relays\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed Relays:\u003c\/strong\u003e 1 trouble relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Contact Rating:\u003c\/strong\u003e 2 A at 30 VDC or 0.5 A at 30 VAC, resistive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass B NAC End-of-Line Resistor:\u003c\/strong\u003e 4.7 kOhm, 0.5 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported ELR Range:\u003c\/strong\u003e 1.9 kOhm to 22 kOhm\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003ePower and Battery\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input:\u003c\/strong\u003e 120\/240 VAC, 50\/60 Hz, 2.4 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum AC Wire Size:\u003c\/strong\u003e 14 AWG with 600 V insulation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum System Battery Capacity:\u003c\/strong\u003e 18 Ah\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Battery Charger Capacity:\u003c\/strong\u003e 55 Ah\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Battery Capacity:\u003c\/strong\u003e Up to two 26 Ah batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eEnvironmental and Physical Specifications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32°F to 120°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Ambient Temperature:\u003c\/strong\u003e 60°F to 80°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 93% +\/- 2%, noncondensing, at 90°F +\/- 3°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor Dimensions:\u003c\/strong\u003e 20.3\" H x 20.6\" W x 0.7\" D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackbox Dimensions:\u003c\/strong\u003e 20\" H x 20.5\" W x 6.8\" D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Dimensions:\u003c\/strong\u003e 22.1\" H x 23.9\" W x 7.8\" D\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e 41 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch4\u003eStandards and Approvals\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Standard:\u003c\/strong\u003e UL 864, 10th edition\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Listing:\u003c\/strong\u003e S624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eULC Listing:\u003c\/strong\u003e S624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSFM Listing:\u003c\/strong\u003e 7165-0075:0500\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFDNY Approval:\u003c\/strong\u003e COA 2023-TMCOAP-006158-CERT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM Approval:\u003c\/strong\u003e FM Approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFPA 72 Applications:\u003c\/strong\u003e Local, auxiliary, remote station, proprietary, central station, DAC, and PSDN systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat's In the Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eES-1000X main circuit board with display\u003c\/li\u003e\n\u003cli\u003ePreinstalled IPOTS-COM communicator\u003c\/li\u003e\n\u003cli\u003eChassis with transformer\u003c\/li\u003e\n\u003cli\u003eBackbox with dress panel and door\u003c\/li\u003e\n\u003cli\u003eHardware bag with screws, cables, and key\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Fire-Lite","offers":[{"title":"Default Title","offer_id":46656313753797,"sku":"FIRE-ES-1000X","price":2330.28,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0630\/3085\/3829\/files\/1-fire-lite-es-1000x_dbda81f1-832e-4b4f-b1f5-7fb136484ac8.jpg?v=1785799107","url":"https:\/\/avlgear.com\/products\/fire-lite-es-1000x-954-point-addressable-fire-alarm-control-panel","provider":"AVLGEAR","version":"1.0","type":"link"}