{"product_id":"honeywell-power-fire-alarm-power-supply","title":"Honeywell Power Fire Alarm Power Supply","description":"\u003ch2\u003eHoneywell Power HPF-PS6\/HPF-PS10 Fire Alarm Power Supply\u003c\/h2\u003e\n\u003cp\u003eThe Honeywell Power HPF-PS6\/HPF-PS10 fire alarm power supply provides 24 VDC notification and auxiliary power with integrated battery charging. Choose the HPF-PS6 for 6A total capacity and five outputs, or the HPF-PS10 for 10A and seven outputs. Both models feature independently configurable circuits inside a red, locking steel enclosure.\u003c\/p\u003e\n\u003cp\u003eDesigned for professional fire alarm installations, these supplies support notification appliance circuits (NACs), four-wire smoke detectors, annunciators, and door holders. Select the 6 amp remote power supply for applications requiring fewer circuits. Choose the 10 amp battery charger supply when your design calls for additional current capacity and output connections. Each version supports constant or resettable auxiliary power.\u003c\/p\u003e\n\u003cp\u003eBoth versions accept 120 VAC input and interface with compatible 12V or 24V fire alarm control panels (FACPs). They support UL 864 panels using standard reverse-polarity notification circuits, plus synchronization for System Sensor, Wheelock, Gentex, and AMSECO appliances. Onboard configuration switches simplify setup, while individual circuit indicators and stored trouble history assist service technicians. Class A operation requires the separately sold ZNAC-PS converter card.\u003c\/p\u003e\n\n\u003ch2\u003eModel Options: Amperage and Output Differences\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS6:\u003c\/strong\u003e 6A maximum combined continuous output, five independently configurable outputs, and two isolated control inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS10:\u003c\/strong\u003e 10A maximum combined continuous output, seven independently configurable outputs, and three isolated control inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Allocation:\u003c\/strong\u003e Total capacity applies across all outputs combined. Individual terminal ratings depend on regulated or special-application operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Distribution:\u003c\/strong\u003e Assign inputs to outputs to accommodate notification, auxiliary, and door holder circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Circuit Wiring:\u003c\/strong\u003e Use Class B circuits or add the optional converter for Class A wiring without sacrificing outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Notification Patterns:\u003c\/strong\u003e Configure ANSI Temporal 3 or Temporal 4 coded operation for the application.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAppliance Synchronization:\u003c\/strong\u003e Coordinate supported notification devices through panel signals, control modules, or cascaded supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Charging:\u003c\/strong\u003e Charge supported lead-acid batteries up to 33 Ah with an external battery cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService Diagnostics:\u003c\/strong\u003e Check individual power and trouble indicators, stored fault history, and dedicated trouble relays.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccessible Installation:\u003c\/strong\u003e Route wiring through ten double knockouts and remove the cabinet door for improved access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOnboard Setup:\u003c\/strong\u003e Configure operating functions through DIP switches without additional software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications: Model-Specific Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS6 Total Output:\u003c\/strong\u003e 6A maximum continuous, combined across five circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS6 Control Inputs:\u003c\/strong\u003e Two fully isolated circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS6 AC Input:\u003c\/strong\u003e 120 VAC, 50\/60 Hz; 5A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS6 Regulated Terminal Ratings:\u003c\/strong\u003e TB8-TB9: 1A per circuit; TB10-TB12: 0.3A per circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS10 Total Output:\u003c\/strong\u003e 10A maximum continuous, combined across seven circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS10 Control Inputs:\u003c\/strong\u003e Three fully isolated circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS10 AC Input:\u003c\/strong\u003e 120 VAC, 50\/60 Hz; 6.2A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHPF-PS10 Regulated Terminal Ratings:\u003c\/strong\u003e TB8-TB11: 1.5A per circuit; TB12-TB14: 0.3A per circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecial-Application Terminal Rating:\u003c\/strong\u003e Both models support up to 3A per output, subject to the combined model limit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications: Shared Electrical Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC, filtered.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e Class B or optional Class A; resettable or non-resettable auxiliary power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClass A Accessory:\u003c\/strong\u003e ZNAC-PS converter card, sold separately.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrigger Voltage:\u003c\/strong\u003e 9-32 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrigger Current Per Input:\u003c\/strong\u003e 1 mA at 9-16V; 2 mA at 16-32V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrouble Relays:\u003c\/strong\u003e Two Form C relays for AC and general trouble; normally closed contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrouble Contact Rating:\u003c\/strong\u003e 4A at 24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnd-of-Line Supervision:\u003c\/strong\u003e Normal resistance range of 2-27 kilohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Fault Detection:\u003c\/strong\u003e Selectable enabled or disabled operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Trouble Reporting:\u003c\/strong\u003e Delay timer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCascading:\u003c\/strong\u003e Up to four supplies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Wiring:\u003c\/strong\u003e 12-14 AWG with 600V insulation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemovable Terminal Capacity:\u003c\/strong\u003e Accepts wire up to 12 AWG.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBattery Charging and Cabinet Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Chemistry:\u003c\/strong\u003e Lead-acid only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFloat-Charge Voltage:\u003c\/strong\u003e 27.6 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Charging Current:\u003c\/strong\u003e 1.5A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Battery Accommodation:\u003c\/strong\u003e Two 7 Ah or two 18 Ah batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Charging Capacity:\u003c\/strong\u003e 33 Ah with batteries in a separate cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCharger Control:\u003c\/strong\u003e DIP-switch disable function supports applications using an external charger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure:\u003c\/strong\u003e Locking steel cabinet with powder-coated finish, removable door, and ten double knockouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor:\u003c\/strong\u003e Red.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 20\" H x 14.5\" W x 3.5\" D.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigured Weight:\u003c\/strong\u003e 24 lb with two 7 Ah batteries; 39 lb with two 18 Ah batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e NFPA 72; UL 864 in NAC expander mode; UL 1481.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePublished Approvals:\u003c\/strong\u003e UL listing S24562; CSFM 7315-1637:0505; FDNY COA 2022-TMCOAP-002231-AMND; FM Approved. Approval applicability depends on configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e USA.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"6 \/ 5-Output","offer_id":50993845665989,"sku":"HON-HPFPS6","price":588.7,"currency_code":"USD","in_stock":true},{"title":"10 \/ 7-Output","offer_id":50993845698757,"sku":"HON-HPFPS10","price":677.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0630\/3085\/3829\/files\/1-honeywell-hpf-ps6_64b3ff25-db99-4271-a5dc-33ac4056613f.jpg?v=1794866271","url":"https:\/\/avlgear.com\/products\/honeywell-power-fire-alarm-power-supply","provider":"AVLGEAR","version":"1.0","type":"link"}