{"product_id":"kidde-fx-278-intelligent-addressable-double-action-fire-alarm-pull-station","title":"Kidde FX-278 Intelligent Addressable Double-Action Fire Alarm Pull Station","description":"\u003ch2\u003eKidde FX-278 Intelligent Addressable Double-Action Fire Alarm Pull Station\u003c\/h2\u003e\n\n\u003cp\u003eThe Kidde FX-278 Intelligent Addressable Double-Action Fire Alarm Pull Station provides manual fire alarm activation for compatible Kidde FX-64 and FX-1000 intelligent fire alarm systems. Featuring a two-step activation mechanism, rotary device addressing, and an integrated microprocessor, this commercial fire alarm station combines supervised alarm signaling with a durable Lexan housing and keyed reset functionality.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for commercial buildings, offices, educational facilities, institutional properties, and professional fire protection installations, the FX-278 allows occupants to manually initiate a fire alarm through a controlled two-action process. Users first raise the protective upper cover marked \"LIFT THEN PULL HANDLE\" and then pull the exposed alarm lever. This arrangement helps reduce accidental activation while maintaining straightforward emergency operation. A factory-installed intelligent input module monitors the station and communicates alarm conditions to the connected fire alarm control panel. Its addressable architecture enables system operators to identify the activated device, making the FX-278 suitable for commercial fire alarm systems requiring individual device supervision and centralized monitoring.\u003c\/p\u003e\n\n\u003cp\u003eThe FX-278 integrates with Kidde FX Series intelligent fire alarm control panels through a supervised signaling line circuit (SLC). Two rotary switches allow installers to configure individual device addresses without specialized addressing equipment. The onboard microprocessor processes device information locally, while diagnostic LEDs indicate normal communication and alarm conditions. Once activated, the station maintains its alarm state until manually reset, supporting controlled system restoration. Its electrical design accommodates conventional fire alarm wiring without requiring twisted or shielded conductors. The ADA-compliant assembly supports installation in standard North American electrical boxes and operates in ambient temperatures up to 120°F.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDouble-Action Alarm Activation:\u003c\/strong\u003e Requires occupants to lift the protective cover before pulling the alarm handle, helping prevent unintended activation while maintaining accessible emergency operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Addressable Communication:\u003c\/strong\u003e Integrates with compatible Kidde FX-64 and FX-1000 fire alarm control panels for individual device identification and supervised alarm reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Microprocessor:\u003c\/strong\u003e Processes device status locally and communicates with the fire alarm system to support responsive alarm monitoring and intelligent system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotary Device Addressing:\u003c\/strong\u003e Features two adjustable rotary switches for assigning individual device addresses during installation and system configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic LED Indicators:\u003c\/strong\u003e Provides green and red status indicators for monitoring normal communication and activated alarm conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyed Manual Reset:\u003c\/strong\u003e Incorporates a secured Lexan enclosure and latching alarm mechanism that requires manual restoration after activation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Wiring and Installation:\u003c\/strong\u003e Supports compatible conventional fire alarm wiring without requiring twisted or shielded cable, simplifying system upgrades and new installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADA-Compliant Design:\u003c\/strong\u003e Supports accessible installation requirements and operates in commercial environments with temperatures ranging from 32 to 120°F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Kidde Commercial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e FX-278\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributor Part Number:\u003c\/strong\u003e ED-FX278\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e FX\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Intelligent Addressable Manual Fire Alarm Pull Station\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePull Station Configuration:\u003c\/strong\u003e Double-Action\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActivation Method:\u003c\/strong\u003e Lift Protective Cover and Pull Alarm Handle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Configuration:\u003c\/strong\u003e Normally Open Dry Contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Operation:\u003c\/strong\u003e Latching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Method:\u003c\/strong\u003e Manual Reset with Secured Cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressable:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing Method:\u003c\/strong\u003e Dual Rotary Address Switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Address Range for 64-Point SLC:\u003c\/strong\u003e 01 to 64\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Address Range for 250-Point Control Panel:\u003c\/strong\u003e 01 to 125\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Addresses Required:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Technology:\u003c\/strong\u003e Intelligent Analog Addressable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e Supervised Signaling Line Circuit (SLC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Line Voltage:\u003c\/strong\u003e Maximum 20 V Peak-to-Peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandby Current:\u003c\/strong\u003e 350 Microamperes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eActivated Current:\u003c\/strong\u003e 500 Microamperes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Electronics:\u003c\/strong\u003e Single-Input Addressable Mini Module with Microprocessor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Installation:\u003c\/strong\u003e Factory Installed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e Red and Green LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Status Indication:\u003c\/strong\u003e Flashing Green LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Status Indication:\u003c\/strong\u003e Flashing Red LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Reset Requirement:\u003c\/strong\u003e Manual Station Reset Before Control Panel Reset\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Fire Alarm Control Panels:\u003c\/strong\u003e Kidde FX-64 and FX-1000 Intelligent Systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Wiring Sizes:\u003c\/strong\u003e 12, 14, 16, and 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreferred Wiring Sizes:\u003c\/strong\u003e 16 or 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded Wiring Requirement:\u003c\/strong\u003e Not Required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwisted-Pair Wiring Requirement:\u003c\/strong\u003e Not Required\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Configuration:\u003c\/strong\u003e Power-Limited and Supervised\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Polarity:\u003c\/strong\u003e Polarity Sensitive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Electrical Box:\u003c\/strong\u003e North American Single-Gang Box, 2.5\" Deep\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlternative Electrical Box:\u003c\/strong\u003e Standard 4\" Square Box, 1.5\" Deep, with Single-Gang Cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Lexan\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Color:\u003c\/strong\u003e Red\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCover Security:\u003c\/strong\u003e Keyed Release\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32 to 120°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -4 to 140°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Relative Humidity:\u003c\/strong\u003e 0% to 93%, Non-Condensing at 90°F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADA Compliance:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum ADA Mounting Height:\u003c\/strong\u003e 48\" Above Finished Floor, Subject to Applicable Installation Requirements\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Standard:\u003c\/strong\u003e NFPA 72 and CAN\/ULC-S524\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 793016036674\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation and System Compatibility\u003c\/h2\u003e\n\n\u003ch2\u003eCompatible Fire Alarm Systems\u003c\/h2\u003e\n\u003cp\u003eThe Kidde FX-278 is designed for compatible FX-64 and FX-1000 intelligent fire alarm control panels. Its integrated addressable input module communicates with the control panel through the supervised signaling line circuit. The device requires an assigned address and must be configured according to the connected system's available address range.\u003c\/p\u003e\n\n\u003ch2\u003eElectrical Box and Wiring Requirements\u003c\/h2\u003e\n\u003cp\u003eThe pull station mounts to a standard North American 2.5\" deep single-gang electrical box or a 1.5\" deep, 4\" square electrical box with an appropriate single-gang cover. Supported conductor sizes include 12, 14, 16, and 18 AWG, with 16 or 18 AWG preferred. Installation wiring must maintain the correct polarity and follow the connected control panel's requirements.\u003c\/p\u003e\n\n\u003ch2\u003eAlarm Activation and Reset\u003c\/h2\u003e\n\u003cp\u003eTo activate the station, raise the protective upper door and pull the alarm handle. The internal contact closes, allowing the integrated module to report an alarm condition to the control panel. The activated station maintains its alarm state until a technician or authorized operator manually resets the mechanism. The fire alarm control panel can then be reset according to established system procedures.\u003c\/p\u003e\n\n\u003cp\u003eThe FX-278 requires electrical power from a compatible fire alarm system and does not operate independently. Installation, inspection, testing, and maintenance must follow the manufacturer's instructions and applicable fire protection regulations.\u003c\/p\u003e","brand":"Kidde","offers":[{"title":"Default Title","offer_id":50997884649669,"sku":"KIDD-FX278","price":162.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0630\/3085\/3829\/files\/1-kidde-fx-278_d8b27ec0-b85c-400d-a5a9-700afa69d8f1.jpg?v=1794931466","url":"https:\/\/avlgear.com\/products\/kidde-fx-278-intelligent-addressable-double-action-fire-alarm-pull-station","provider":"AVLGEAR","version":"1.0","type":"link"}