{"product_id":"kidde-kir-osd-optica-intelligent-addressable-photoelectric-smoke-detector","title":"Kidde KIR-OSD Optica Intelligent Addressable Photoelectric Smoke Detector","description":"\u003ch2\u003eKidde KIR-OSD Optica Intelligent Addressable Photoelectric Smoke Detector\u003c\/h2\u003e\n\n\u003cp\u003eThe Kidde KIR-OSD Optica Intelligent Addressable Photoelectric Smoke Detector is a rotary-addressed fire detection device designed for compatible Kidde FX Series fire alarm systems. Using multi-criteria optical sensing technology, it analyzes airborne particles to identify smoke while reducing nuisance alarms caused by common environmental conditions, including cooking-related particulates and steam.\u003c\/p\u003e\n\n\u003cp\u003eDesigned for commercial buildings, offices, educational facilities, healthcare environments, and professional fire alarm installations, the KIR-OSD combines dual-wavelength optical sensing with multiple detection angles to improve smoke recognition. Its onboard microprocessor processes sensor readings through digital filtering algorithms, helping distinguish combustion-related smoke from non-fire particles. Five programmable sensitivity settings and 20 pre-alarm configurations provide flexibility for different installation environments. Automatic day\/night sensitivity adjustments allow compatible fire alarm control panels to adapt detection parameters to changing occupancy conditions. The detector also supports up to 250 intelligent device addresses per compatible signaling loop, making it suitable for larger addressable fire alarm networks.\u003c\/p\u003e\n\n\u003cp\u003eThe KIR-OSD integrates with Kidde fire alarm control panels equipped with an Intelligent Loop controller, including compatible FX Series systems. Rotary address switches simplify device identification, while automatic self-diagnostics and non-volatile memory preserve operational and maintenance information. Two environmental compensation levels and two dirty-detector warning levels help identify conditions requiring maintenance. A bicolor LED provides local status indication. The detector supports standard, relay, fault-isolator, and audible mounting bases for flexible system integration. Listed to UL 268 7th Edition, UL 268A, and CAN\/ULC-S529, the KIR-OSD provides addressable smoke detection for professionally designed fire alarm systems.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Criteria Optical Smoke Detection:\u003c\/strong\u003e Uses dual optical wavelengths and multiple sensing angles to identify smoke particles while helping reject common nuisance sources.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelligent Addressable Communication:\u003c\/strong\u003e Integrates with compatible Kidde FX Series fire alarm panels and supports up to 250 intelligent device addresses per signaling loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable Detection Sensitivity:\u003c\/strong\u003e Offers five sensitivity settings and 20 pre-alarm configurations to accommodate different monitored environments and system requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Environmental Compensation:\u003c\/strong\u003e Provides two compensation levels and two dirty-detector warning levels to support consistent operation and preventive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRotary Device Addressing:\u003c\/strong\u003e Features integrated address switches for assigning detector addresses from 1 to 125 without additional programming hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Self-Diagnostics:\u003c\/strong\u003e Monitors detector condition and stores diagnostic information in non-volatile memory for maintenance and troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Day\/Night Adjustment:\u003c\/strong\u003e Allows compatible control systems to modify smoke sensitivity according to programmed operating schedules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mounting Compatibility:\u003c\/strong\u003e Supports standard, relay, fault-isolator, and audible detector bases for commercial fire alarm installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Kidde Commercial\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e KIR-OSD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributor Part Number:\u003c\/strong\u003e ED-KIROSD\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Series:\u003c\/strong\u003e Optica\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Intelligent Addressable Photoelectric Smoke Detector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector Configuration:\u003c\/strong\u003e Rotary Addressed\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Technology:\u003c\/strong\u003e Multi-Criteria Optical\/Photoelectric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical Sensing:\u003c\/strong\u003e Dual-Wavelength, Multiple Detection Angles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Processing:\u003c\/strong\u003e Microprocessor-Based Digital Filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetection Medium:\u003c\/strong\u003e Airborne Smoke Particles\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke Sensitivity Range:\u003c\/strong\u003e 0.5 to 4.36% per ft Obscuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelectable Sensitivity Settings:\u003c\/strong\u003e 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePre-Alarm Settings:\u003c\/strong\u003e 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Compensation:\u003c\/strong\u003e Automatic, 2 Levels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirty Detector Warning Levels:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic Day\/Night Sensitivity Adjustment:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Diagnostics:\u003c\/strong\u003e Automatic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Storage:\u003c\/strong\u003e Non-Volatile Memory\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Addressing:\u003c\/strong\u003e Dual Rotary Address Switches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Range:\u003c\/strong\u003e 1 to 125\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Intelligent Device Addresses per Loop:\u003c\/strong\u003e 250, Subject to Control Panel Compatibility\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Wired\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Type:\u003c\/strong\u003e Intelligent Digital Communication\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Control Systems:\u003c\/strong\u003e Kidde Fire Alarm Panels Using an Intelligent Loop Controller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Panel Series:\u003c\/strong\u003e Kidde FX Series\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e 15.20 to 19.95 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Operating Current:\u003c\/strong\u003e 43 Microamperes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Current:\u003c\/strong\u003e 70 Microamperes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32 to 120 Degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -4 to 140 Degrees F\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Relative Humidity:\u003c\/strong\u003e 0% to 93%, Non-Condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Velocity Range:\u003c\/strong\u003e 0 to 4000 ft\/min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Frequency Range:\u003c\/strong\u003e 10 to 35 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Amplitude:\u003c\/strong\u003e 0.01\"\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Wall-Mounting Distance from Ceiling:\u003c\/strong\u003e 12\"\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Ceiling or Wall with Compatible Detector Base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e High-Impact Engineering Polymer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHousing Color:\u003c\/strong\u003e White\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Bicolor Green\/Red LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Standard Bases:\u003c\/strong\u003e KI-SB, KI-SB4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Relay Bases:\u003c\/strong\u003e KI-RB, KI-RB4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Fault-Isolator Bases:\u003c\/strong\u003e KI-IB, KI-IB4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Audible Bases:\u003c\/strong\u003e KI-ABST, KI-ABDT, KI-ABLT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Remote Alarm Indicator:\u003c\/strong\u003e GSA-LED with KI-SB or KI-SB4 Base\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Detector Testing Equipment:\u003c\/strong\u003e Testifire 1000, Testifire 2000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Mounting Boxes:\u003c\/strong\u003e North American 1-Gang, 3.5\"\" Octagonal, 4\"\" Octagonal, and Supported 4\"\" Square Electrical Boxes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Wiring Sizes:\u003c\/strong\u003e 12, 14, 16, and 18 AWG Through Compatible Detector Bases\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecommended Wiring Sizes:\u003c\/strong\u003e 16 or 18 AWG\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Wiring Resistance:\u003c\/strong\u003e 10 Ohms per Wire\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL Certification:\u003c\/strong\u003e UL 268 7th Edition, UL 268A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCanadian Certification:\u003c\/strong\u003e CAN\/ULC-S529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional Listing:\u003c\/strong\u003e CSFM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of Origin:\u003c\/strong\u003e China\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUPC:\u003c\/strong\u003e 793016061157\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation and Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe Kidde KIR-OSD requires a compatible Kidde Intelligent Loop controller and an appropriate detector mounting base. Installers assign a unique device address through the two rotary switches located on the detector. The control panel can identify duplicate addresses during system configuration.\u003c\/p\u003e\n\n\u003cp\u003eCompatible mounting bases include the KI-SB and KI-SB4 standard bases, KI-RB and KI-RB4 relay bases, and KI-IB and KI-IB4 fault-isolator bases. Supported audible bases include the KI-ABST, KI-ABDT, and KI-ABLT. Base selection depends on the system design, required signaling functions, and mounting configuration.\u003c\/p\u003e\n\n\u003cp\u003eThe detector is intended for professionally designed addressable fire alarm systems. Installation, testing, wiring, and maintenance must follow the manufacturer's instructions, applicable fire alarm standards, and local authority requirements. Advanced features such as sensitivity adjustment, pre-alarm functions, and maintenance reporting depend on the connected control panel.\u003c\/p\u003e\"","brand":"Kidde","offers":[{"title":"Default Title","offer_id":50997884780741,"sku":"KIDD-KIROSD","price":75.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0630\/3085\/3829\/files\/1-kidde-kir-osd_b7792118-a187-4a80-b0c9-385c4de7ce67.jpg?v=1794931481","url":"https:\/\/avlgear.com\/products\/kidde-kir-osd-optica-intelligent-addressable-photoelectric-smoke-detector","provider":"AVLGEAR","version":"1.0","type":"link"}