Used: Bent on microphone grille. Still functions normally.
Neumann TLM 103 Cardioid Mic with K103 Capsule, includes SG1 and Woodbox Nickel
The Neumann TLM103 Cardioid Mic with K103 Capsule, includes SG1 and Woodbox | Nickel is the ideal large diaphragm microphone for all professional and semi-professional applications requiring the utmost in sound quality on a limited budget.
By utilizing the tried and true transformerless circuit found in numerous Neumann microphones, the TLM 103 features yet unattained low self-noise and the highest sound pressure level transmission. The capsule, derived from that used in the U 87, has a cardioid pattern, is acoustically well-balanced and provides extraordinary attenuation of signals from the rear.
The TLM 103 is available in satin nickel and matte black. Delivery includes an SG 1 metal swivel mount and a wooden jeweler's box.
Applications
Due to the universal cardioid pattern, straightforward handling, extremely low self-noise level, and finally, the price, the TLM 103 is predestined for all demanding applications from home recording to professional broadcasting and commercial recording studios.
Polar pattern
The TLM 103 is equipped with a large diaphragm capsule with cardioid pattern. By focusing on this pattern – used in most recording situations – the attenuation of unwanted rear sound has been optimized. Off-axis sounds are rendered naturally while isolation is increased. This also leads to a high feedback suppression when the microphone is used in live situations or where loudspeaker playback is a factor.
Key Features
Large-diaphragm microphone
Pressure gradient transducer with with one-diaphragm capsule
Transformerless circuitry
Extremely low noise: 7 dB-AIncludes swivel moun
Includes swivel mount
Straightforward handling for homerecording and professional studios
High-quality professional equipment for limited budgets
Technical Specs
Acoustical operating principle
Pressure gradient transducer
Directional pattern
Cardioid
Frequency range
20 Hz ... 20 kHz
Sensitivity at 1 kHz into 1 kohm
23 mV/Pa
Rated impedance
50 ohms
Rated load impedance
1 kohms
Equivalent noise level, CCIR
17.5 dB
Equivalent noise level, A-weighted
7 dB-A
Signal-to-noise ratio, CCIR (rel. 94 dB SPL)
76.5 dB
Signal-to-noise ratio, A-weighted (rel. 94 dB SPL)
87 dB-A
Maximum SPL for THD 0.5 %
138 dB
Maximum output voltage
13 dBu
Dyn. range of the mic. amplifier (A-weighted, 0.5 %)
131 dB
Supply voltage (P48, IEC 61938)
48 V ± 4 V
Current consumption (P48, IEC 61938)
3 mA
Matching connector
XLR 3F
Weight
450 g, 1 lbs
Diameter
60 mm
Length
132 mm