Kidde FX-278 Intelligent Addressable Double-Action Fire Alarm Pull Station
The Kidde FX-278 Intelligent Addressable Double-Action Fire Alarm Pull Station provides manual fire alarm activation for compatible Kidde FX-64 and FX-1000 intelligent fire alarm systems. Featuring a two-step activation mechanism, rotary device addressing, and an integrated microprocessor, this commercial fire alarm station combines supervised alarm signaling with a durable Lexan housing and keyed reset functionality.
Designed for commercial buildings, offices, educational facilities, institutional properties, and professional fire protection installations, the FX-278 allows occupants to manually initiate a fire alarm through a controlled two-action process. Users first raise the protective upper cover marked "LIFT THEN PULL HANDLE" and then pull the exposed alarm lever. This arrangement helps reduce accidental activation while maintaining straightforward emergency operation. A factory-installed intelligent input module monitors the station and communicates alarm conditions to the connected fire alarm control panel. Its addressable architecture enables system operators to identify the activated device, making the FX-278 suitable for commercial fire alarm systems requiring individual device supervision and centralized monitoring.
The FX-278 integrates with Kidde FX Series intelligent fire alarm control panels through a supervised signaling line circuit (SLC). Two rotary switches allow installers to configure individual device addresses without specialized addressing equipment. The onboard microprocessor processes device information locally, while diagnostic LEDs indicate normal communication and alarm conditions. Once activated, the station maintains its alarm state until manually reset, supporting controlled system restoration. Its electrical design accommodates conventional fire alarm wiring without requiring twisted or shielded conductors. The ADA-compliant assembly supports installation in standard North American electrical boxes and operates in ambient temperatures up to 120°F.
Key Features
- Double-Action Alarm Activation: Requires occupants to lift the protective cover before pulling the alarm handle, helping prevent unintended activation while maintaining accessible emergency operation.
- Intelligent Addressable Communication: Integrates with compatible Kidde FX-64 and FX-1000 fire alarm control panels for individual device identification and supervised alarm reporting.
- Integrated Microprocessor: Processes device status locally and communicates with the fire alarm system to support responsive alarm monitoring and intelligent system operation.
- Rotary Device Addressing: Features two adjustable rotary switches for assigning individual device addresses during installation and system configuration.
- Diagnostic LED Indicators: Provides green and red status indicators for monitoring normal communication and activated alarm conditions.
- Keyed Manual Reset: Incorporates a secured Lexan enclosure and latching alarm mechanism that requires manual restoration after activation.
- Flexible Wiring and Installation: Supports compatible conventional fire alarm wiring without requiring twisted or shielded cable, simplifying system upgrades and new installations.
- ADA-Compliant Design: Supports accessible installation requirements and operates in commercial environments with temperatures ranging from 32 to 120°F.
Technical Specifications
- Brand: Kidde Commercial
- Manufacturer Part Number: FX-278
- Distributor Part Number: ED-FX278
- Product Series: FX
- Product Type: Intelligent Addressable Manual Fire Alarm Pull Station
- Pull Station Configuration: Double-Action
- Activation Method: Lift Protective Cover and Pull Alarm Handle
- Contact Configuration: Normally Open Dry Contact
- Alarm Operation: Latching
- Reset Method: Manual Reset with Secured Cover
- Addressable: Yes
- Addressing Method: Dual Rotary Address Switches
- Device Address Range for 64-Point SLC: 01 to 64
- Device Address Range for 250-Point Control Panel: 01 to 125
- Device Addresses Required: 1
- Communication Technology: Intelligent Analog Addressable
- Communication Interface: Supervised Signaling Line Circuit (SLC)
- Communication Line Voltage: Maximum 20 V Peak-to-Peak
- Standby Current: 350 Microamperes
- Activated Current: 500 Microamperes
- Integrated Electronics: Single-Input Addressable Mini Module with Microprocessor
- Module Installation: Factory Installed
- Diagnostic Indicators: Red and Green LEDs
- Normal Status Indication: Flashing Green LED
- Alarm Status Indication: Flashing Red LED
- Alarm Reset Requirement: Manual Station Reset Before Control Panel Reset
- Compatible Fire Alarm Control Panels: Kidde FX-64 and FX-1000 Intelligent Systems
- Supported Wiring Sizes: 12, 14, 16, and 18 AWG
- Preferred Wiring Sizes: 16 or 18 AWG
- Shielded Wiring Requirement: Not Required
- Twisted-Pair Wiring Requirement: Not Required
- Wiring Configuration: Power-Limited and Supervised
- Wiring Polarity: Polarity Sensitive
- Compatible Electrical Box: North American Single-Gang Box, 2.5" Deep
- Alternative Electrical Box: Standard 4" Square Box, 1.5" Deep, with Single-Gang Cover
- Housing Material: Lexan
- Housing Color: Red
- Cover Security: Keyed Release
- Operating Temperature: 32 to 120°F
- Storage Temperature: -4 to 140°F
- Operating Relative Humidity: 0% to 93%, Non-Condensing at 90°F
- ADA Compliance: Yes
- Maximum ADA Mounting Height: 48" Above Finished Floor, Subject to Applicable Installation Requirements
- Installation Standard: NFPA 72 and CAN/ULC-S524
- Country of Origin: China
- UPC: 793016036674
Installation and System Compatibility
Compatible Fire Alarm Systems
The Kidde FX-278 is designed for compatible FX-64 and FX-1000 intelligent fire alarm control panels. Its integrated addressable input module communicates with the control panel through the supervised signaling line circuit. The device requires an assigned address and must be configured according to the connected system's available address range.
Electrical Box and Wiring Requirements
The pull station mounts to a standard North American 2.5" deep single-gang electrical box or a 1.5" deep, 4" square electrical box with an appropriate single-gang cover. Supported conductor sizes include 12, 14, 16, and 18 AWG, with 16 or 18 AWG preferred. Installation wiring must maintain the correct polarity and follow the connected control panel's requirements.
Alarm Activation and Reset
To activate the station, raise the protective upper door and pull the alarm handle. The internal contact closes, allowing the integrated module to report an alarm condition to the control panel. The activated station maintains its alarm state until a technician or authorized operator manually resets the mechanism. The fire alarm control panel can then be reset according to established system procedures.
The FX-278 requires electrical power from a compatible fire alarm system and does not operate independently. Installation, inspection, testing, and maintenance must follow the manufacturer's instructions and applicable fire protection regulations.