Kidde KIR-HD Intelligent Fixed Temperature and Rate-of-Rise Heat Detector
Estimated Shipping Widget will be displayed here!
Condition: New
Description
Kidde KIR-HD Intelligent Fixed Temperature and Rate-of-Rise Heat Detector
The Kidde KIR-HD Intelligent Fixed Temperature and Rate-of-Rise Heat Detector is an addressable fire detection device designed for compatible Kidde FX Series fire alarm systems. It monitors surrounding air temperature and activates an alarm when temperatures reach the 135°F fixed-temperature threshold or when a programmed rate-of-rise condition is detected.
Designed for commercial fire alarm installations, industrial facilities, laundry rooms, and environments where conventional smoke detection may be unsuitable, the KIR-HD provides dependable thermal monitoring through advanced thermistor sensing technology. Its programmable rate-of-rise function detects rapid temperature increases of 15°F per minute, helping identify developing fire conditions before the fixed-temperature threshold is reached. The detector supports installation spacing of up to 50 feet under applicable installation requirements. Its intelligent communication architecture supports up to 250 devices per compatible signaling loop, making it suitable for large commercial fire alarm networks. Existing compatible wiring can also be reused during system upgrades, helping simplify installation and reduce unnecessary infrastructure modifications.
The KIR-HD incorporates automatic self-diagnostics, non-volatile memory, and rotary address switches for straightforward system configuration and maintenance. Its integrated green and red LED provides visual indication of normal operation and alarm conditions. Compatible standard, relay, fault-isolator, and audible mounting bases offer flexibility for different fire alarm applications. The detector operates with compatible Kidde FX Series intelligent fire alarm control panels and complies with UL 521 and applicable Canadian fire detection standards. Its white housing supports ceiling or wall installation using an appropriate detector base.
Key Features
- Dual-Mode Heat Detection: Provides a 135°F fixed-temperature alarm threshold with an optional programmable rate-of-rise function for detecting rapid temperature increases.
- Intelligent Addressable Operation: Communicates with compatible FX Series fire alarm panels, supporting individual device identification and system monitoring.
- Programmable Rate-of-Rise Detection: Detects temperature increases of 15°F per minute when enabled through a compatible control system.
- Automatic Self-Diagnostics: Continuously monitors detector performance and stores diagnostic information in non-volatile memory for maintenance and troubleshooting.
- Rotary Addressing: Features two adjustable address switches that simplify device identification and configuration during installation.
- Dual-Color Status Indicator: Uses a green LED to indicate normal operation and a red LED to indicate alarm activation.
- Flexible Mounting Compatibility: Supports standard, relay, fault-isolator, and audible detector bases for different commercial fire alarm configurations.
- Extended System Integration: Supports installations with up to 250 devices per compatible loop and maximum detector spacing of 50 feet, subject to applicable installation requirements.
Technical Specifications
- Brand: Kidde Commercial
- Manufacturer: Kidde Fire and Safety
- Manufacturer Part Number: KIR-HD
- Distributor Part Number: ED-KIRHD
- Product Series: KI
- Product Type: Intelligent Addressable Heat Detector
- Detection Technology: Thermistor-Based Heat Sensing
- Detection Modes: Fixed Temperature and Programmable Rate-of-Rise
- UL Fixed-Temperature Alarm Rating: 135°F
- ULC Fixed-Temperature Alarm Rating: 140°F
- Rate-of-Rise Alarm Threshold: 15°F per Minute
- Maximum Detector Spacing: 50 ft on Centers
- Maximum Devices per Loop: 250, Subject to Control Panel Compatibility
- Addressable: Yes
- Address Configuration: Dual Rotary Address Switches
- Connectivity: Wired
- Communication: Intelligent Digital Communication
- Compatible Control Panels: Kidde FX Series Intelligent Fire Alarm Panels
- Operating Voltage: 15.2 to 19.95 VDC
- Normal Operating Current: 51 µA Average
- Alarm Current: 68 µA Average
- Operating Temperature: 32 to 120°F
- Storage Temperature: -4 to 140°F
- Operating Relative Humidity: 0% to 93%, Non-Condensing
- Maximum Wall-Mounting Distance from Ceiling: 12"
- Mounting Configuration: Ceiling or Wall Mount
- Housing Color: White
- Status Indicator: Bicolor Green/Red LED
- Normal Status Indication: Flashing Green LED
- Alarm Status Indication: Flashing Red LED
- Self-Diagnostics: Automatic
- Diagnostic Storage: Non-Volatile Memory
- Compatible Standard Bases: KI-SB, KI-SB4
- Compatible Relay Bases: KI-RB, KI-RB4
- Compatible Fault-Isolator Bases: KI-IB, KI-IB4
- Compatible Audible Bases: KI-ABST, KI-ABDT, KI-ABLT
- Compatible Remote LED: GSA-LED with Supported Standard Bases
- Supported Mounting Boxes: North American 1-Gang, 3.5" Octagonal, 4" Octagonal, and Compatible 4" Square Electrical Boxes
- Supported Wire Sizes: 12, 14, 16, and 18 AWG Through Compatible Mounting Bases
- Recommended Wire Sizes: 16 or 18 AWG
- Maximum Wiring Resistance: 10 Ohms per Wire
- Environmental Compensation: Automatic
- Standards: UL 521, ULC-S530-M91, CAN/ULC S524-01
- Manufacturing Quality Standard: ISO 9001
- FCC Compliance: Part 15
- Country of Origin: China
- UPC: 793016053275
Installation and System Compatibility
The Kidde KIR-HD is designed for compatible FX Series intelligent fire alarm control panels. Installers assign each detector a unique address using the rotary switches on the rear of the device. The detector then attaches to a compatible mounting base through a twist-lock connection.
Compatible mounting options include the KI-SB standard base, KI-RB relay base, KI-IB fault-isolator base, and supported KI Series audible bases. Mounting bases are separate components and must be selected according to the installation's fire alarm system requirements.
The KIR-HD detects heat rather than smoke, flames, or combustion gases. It must be installed as part of an appropriately designed fire protection system in accordance with applicable codes, manufacturer instructions, and the requirements of the local authority having jurisdiction.